Probes:
Oscilloscope Probes
Analog Oscilloscope:
20 MHz: | OS-45020 |
25 MHz: | OS-22251 |
40 MHz: | OS-22405 | OS-45040 |
60 MHz: | OS-22600 | OS-22605 |
100 MHz: | OS-221000 | OS-221005 | |
Digital Oscilloscope:
25~200 MHz: DSO-55XXXC series
20 MHz: DSO-3200C
150 MHz: DSO-51150
250 MHz: DSO-51250C
|
OS-45020: Oscilloscope(20 MHz) |
Specifications:
CRT |
Type |
6" rectangle, internal graticule |
Display area |
8 x 10DIV (1DIV = 10mm) |
Accelerating voltage |
1.9KV |
Brightness and focusing |
Controlled at the front panel |
Trace rotation |
Adjusted at the front panel |
VERTICAL SYSTEM |
Sensitivity and accuracy |
5mV ~ 20V/DIV, +/- 3% 1mV/DIV ~ 1V/DIV, +/- 5%
(5 times, only CH1) 12 calibration steps in order of 1-2-5 |
Width of band(-3dB) |
DC(AC 10Hz) ~ 20MHz |
Rise time |
<17.5ns |
Input impedance |
1MW +/- 3% 30pF +/- 5pF |
Input coupling |
DC, GND, AC |
Max. input voltage |
400V (DC + ACpeak) |
Vertical mode |
CH1, CH2, DUAL (CHOP, ALT) ADD,CH2 inverse |
CH1 signal output |
25mV/DIV 50W |
|